Intraventricular entrapment of shunt catheter causing shunt malfunction

Authors

  • Amit Agrawal
  • Umamaheswara Reddy V.
  • Yashwant Sandeep

Keywords:

Shunt malfunction, mechanical failure, loculationn, entrappement

Abstract

Intraventricular septations can lead to compartmentalization of the ventricles that can result in “complex or loculated hydrocephalus”. We report a case of 7 year old female child who underwent multiple shunt revisions where there was intraventricular entrapment of shunt catheter leading to obstruction of the shunt and malfunction. In present case we placed the ventricular catheter in contra-lateral ventricle with good clinical outcome. With the recent advancements endoscopic guided removal of the old malfunctioning ventricular catheters is considered the safest option.